Pressure injury prevention INTERMITTENT PRESSURE REDUCTION Due to the alternating 2-cell system, Air2Care reduces pressure and helps to minimise sustained pressure peaks to the patient’s body. LOCALISED PRESSURE OFFLOADING The individual cell construction uses self-sealing valves that allow the cells to be individually deflated. MINIMIZED RISK OF BOTTOMING OUT WHILE SITTING The Single Point Fowler Boost feature enables automatic detection of the raised backrest position.
Patient safety and control The wide choice of cycle times allows caregivers to select the right balance of intermittent pressure reduction and patient comfort. Cycle Time Options of 10/15/20/25 Minutes Choice of appropriate cycle time based on the patient’s condition and individual preference.
Infection control The cell construction makes it possible to completely remove the individual cells for cleaning and decontamination. Self-sealing valves help maintain pressure, so the mattress stays inflated even if a cell is removed for cleaning or repair. Individual cells can be removed so that the entire mattress may be easily cleaned. The mattress cover is vapor permeable and water resistant. The zipper is covered to prevent the ingress of dirt or fluids. The mattress cover has a 360° zipper easy to remove the cover for cleaning.
Easy maintenance Individual cells are quick and easy to replace. Cells can be removed individually and replaced in case of damage. The removable cells with self-sealing valves enable quick and easy replacement of damaged cells without even having to switch off the system.
Easy patient transportation A static transport mode is available during transport or in any situation where the mattress is disconnected from the mains. Transport Mode can provide constant low pressure for 8 hours while disconnected from the power or System Control Unit (SCU).
User friendly control Individual cells are quick and easy to replace. Cells can be removed individually and replaced in case of damage. The removable cells with self-sealing valves enable quick and easy replacement of damaged cells without even having to switch off the system.
Categories Features Air Decks Modes Transport mode Cycle time Fowler Boost Mattress dimension Length (cm) Width (cm) Depth (cm) Additional parameters Maximum patient weight (kg) Minimum patient weight (kg) Cover Zipper Handles
Air2Care 8 Air+Air Alternate, Max, Constant Low Pressure Yes 10, 15, 20, 25 min Single point 200 86/100 20 180/250 40 Waterproof and Vapor Permeable, Stretch Cover 360° Yes
Air2Care 6 Air+Air Alternate, Max, Constant Low Pressure Yes 10, 15, 20, 25 min Single point 200/210 86/90 15 160 40 Waterproof and Vapor Permeable, Stretch Cover 360° Yes
Air2Care 5 Overlay Alternate, Max, Constant Low Pressure Yes 10, 15, 20, 25 min Single point 200 86 12,5 140 40 Waterproof and Vapor Permeable, Stretch Cover 360° Yes
Air2Care 4 Overlay Seating Cushion Alternate, Max, Constant Low Pressure Yes 10, 15, 20 min - 48 46 10 130 40 Waterproof and Vapor Permeable, Stretch Cover 270° -